FAQ Large-Sized Casting Parts,Ebm 3D Printer Provider,Delicate Metal Castings,Delicate Metal Parts Guangdong Fenghua Zhuoli Technology Co., Ltd , https://www.fhzl3dpequip.com
The following Engine brands, Alternator brands and Control panel brands for options:
Rated power
Engine
Alternator
Control panel
 20kw~1300kw
 Cummins
Stamford
Leroy Somer
Marathon
Mecc Alte
ABB
Chinese AlternatorsDeepsea
ComAp
Harsen
Smartgen
 8kw~1600kw
 Perkins
 68kw~504kw
 Volvo
 20kw~500kw
 Deutz
 220kw-2400kw
 MTU
 600kw-1800kw
 Mitsubishi
 50kw-650kw
 Doosan Daewoo
 2kw~2500kw
 Chinese Engines
Perkins Electric Power Diesel Generator with Stamford Alternator
British (also called Rolls-Royce) Engine Co., Ltd is one of the largest engine manufacturers in the world. Perkins is complete in specifications & types, has compact form, reliable performance, convenient maintenance. And the less gas pollution is up to the EU Environmental emission standards.
Â
1. Specification of genset
Genset Model
SFP-800
Prime Power
640KW/800KVA
Rated Voltage
400/230V
Frequency
50/60Hz
Power Factor
0.8(lagging)
The regulating rate of steady voltage
≤±0.5%
The regulating rate of instantaneous voltage
≤-15%/ +20%
The time of steady voltage
≤1.5sec
The waving rate of voltage
≤1.0%
The regulating rate of steady frequency
≤3%
The regulating rate of instantaneous frequency
≤±10%
The time of steady frequency
3sec
Dimension (L×W×H) (mm)
4600*1800*2300
Genset Weight (kg)
6000
2. Specification of diesel engine
Brand
Perkins
Model
4006-23TAG3A
Number of Cylinders
6 in line
Rotating Speed
1500/1800RPM
Cycle
Four stroke
TypeÂ
Waste gas turbine boost, direct spurting typeÂ
Bore×Stroke(mm)
160*190
Displacement(L)
22.9
Lubricating Capacity(L)
113
Speed Governor
ElectricalÂ
Cooling System
Water-cooled
Speed Stability (%)
≤5%
Fuel Consumption at 100% Load
209g/kw.h
Starting Method
DC24V Electrical starting
3. Specification of alternator
Brand
Stamford
Model
LVI634C
Number of Phase
3
Connecting Type
Three Phase and Four Wire
Number of Bearing
1
Grading Protection
IP22
Altitude
≤1000m
Exciter Type
Brushless (AVR automatic voltage regulating)
Insulation Class
H degree
4. Specification of control panel The control panel is Quadruplication protection control panel, with the display of frequency table/water temperature/schedule/battery voltmeter. The genset with low oil pressure, high water temperature, over speed emergency, stop and other pre-protection.
What's your power range of diesel generator?
Answer: We can offer the range from 10kva~3125kva.
Â
What's your delivery time?
Answer: 7 workdays after we get the down payment.
Â
What's your payment?
Answer: T/T, L/C, and 30% T/T as the deposit, the balance payment should be paid before shipping.
Â
What's your warranty?
Answer: One year warranty or 1000 hours which comes first.
Â
What's your MOQ?
Answer: 1 set.
Â
What's your frequency of diesel generator?
Answer: 50/60Hz
Â
What's your voltage of diesel generator?
Answer: 220/110V, 380/220V, 400/230V, 415/240V, 440/260V, 460/270V, and double voltage…
Â
The following Engine brands, Alternator brands and Control panel brands for options:
Rated power
Engine
Alternator
Control panel
 20kw~1300kw
 Cummins
Stamford
Leroy Somer
Marathon
Mecc Alte
ABB
Chinese AlternatorsDeepsea
ComAp
Harsen
Smartgen
 8kw~1600kw
 Perkins
 68kw~504kw
 Volvo
 20kw~500kw
 Deutz
 220kw-2400kw
 MTU
 600kw-1800kw
 Mitsubishi
 50kw-650kw
 Doosan Daewoo
 2kw~2500kw
 Chinese Engines
Perkins Electric Power Diesel Generator with Stamford Alternator
British (also called Rolls-Royce) Engine Co., Ltd is one of the largest engine manufacturers in the world. Perkins is complete in specifications & types, has compact form, reliable performance, convenient maintenance. And the less gas pollution is up to the EU Environmental emission standards.
Â
1. Specification of genset
Genset Model
SFP-800
Prime Power
640KW/800KVA
Rated Voltage
400/230V
Frequency
50/60Hz
Power Factor
0.8(lagging)
The regulating rate of steady voltage
≤±0.5%
The regulating rate of instantaneous voltage
≤-15%/ +20%
The time of steady voltage
≤1.5sec
The waving rate of voltage
≤1.0%
The regulating rate of steady frequency
≤3%
The regulating rate of instantaneous frequency
≤±10%
The time of steady frequency
3sec
Dimension (L×W×H) (mm)
4600*1800*2300
Genset Weight (kg)
6000
2. Specification of diesel engine
Brand
Perkins
Model
4006-23TAG3A
Number of Cylinders
6 in line
Rotating Speed
1500/1800RPM
Cycle
Four stroke
TypeÂ
Waste gas turbine boost, direct spurting typeÂ
Bore×Stroke(mm)
160*190
Displacement(L)
22.9
Lubricating Capacity(L)
113
Speed Governor
Electrical Large-sized Casting Parts
Perkins Electric Power Diesel Generator with Stamford Alternator
Model NO.: SFP-800
Conditions of Use: Land Use
Usage: Common Units
Landuse Type of Unit: Ordinary
Excitation Mode: AC Rotating Exciter
Power: 800kVA/640kw
Voltage: 230/400V
Frequency: 50/60Hz
Test Load: 50%, 75%, 100%, 110%
Noise: Below 75dB in 7m for Silent
Warranty: International Warranty Services
Certificate: ISO, Ce, TUV
Delivery Time: 7 Workdays Against Deposit
Alternator: Stamford, Marathon, Leroy Somer, Mecc Alte
Controller: Deapsea, Comap, Harsen, Smartgen
Trademark: SHUNFENG (OEM Supported)
Transport Package: Wrapping Film/Plywood Case
Specification: Open Type, Canopy, Trailer
Origin: China
HS Code: 8502131000
Model NO.: SFP-800
Conditions of Use: Land Use
Usage: Common Units
Landuse Type of Unit: Ordinary
Excitation Mode: AC Rotating Exciter
Power: 800kVA/640kw
Voltage: 230/400V
Frequency: 50/60Hz
Test Load: 50%, 75%, 100%, 110%
Noise: Below 75dB in 7m for Silent
Warranty: International Warranty Services
Certificate: ISO, Ce, TUV
Delivery Time: 7 Workdays Against Deposit
Alternator: Stamford, Marathon, Leroy Somer, Mecc Alte
Controller: Deapsea, Comap, Harsen, Smartgen
Trademark: SHUNFENG (OEM Supported)
Transport Package: Wrapping Film/Plywood Case
Specification: Open Type, Canopy, Trailer
Origin: China
HS Code: 8502131000