YW liquid sewage pump troubleshooting

malfunction the reason Method of exclusion
Low or no water flow 1, impeller reversed
2, the flow blockage
3, the motor speed is not enough
4, pumping medium concentration is too large
5, head is too high
1, adjust the impeller rotation direction
2, remove debris
3, check the power supply voltage and frequency
4, diluted with water dilute concentration
5, change the pump or reduce head
【Can not start】 1, lack of phase
2, impeller stuck
3, winding, connector or cable break
4, the stator winding burn out
5, electrical control failure
1, check the line, to repair
2, remove debris
3, check with ohmmeter repair
4, to repair, replace the winding
5, check the controller, repair or exchange
Stator burned 1, two-phase operation
2, pumping medium concentration is too large
3, the impeller stuck or loose
4, seal damage to the motor water
5, loose fasteners cause the motor water
1, 饲 逑 chanting punishment fine income
2, diluted with water
3, remove dirt, tighten the nut
4, replace the mechanical seal
5, tighten the various bolts
【Overcurrent】 1, working voltage is low
2, pipes, impeller blocked
3, pumping liquid density or higher viscosity
1, adjust the working voltage
2, clean up the pipeline and impeller blockage
3, change the density or viscosity of pumping liquid
Fault Cause Remedy insufficient flow or no water [1], reverse impeller
2, the flow blockage
3, the motor speed is not enough
4, pumping medium concentration is too large
5, lift too high 1, adjust the impeller rotation direction
2, remove debris
3, check the power supply voltage and frequency
4, diluted with water dilute concentration
5, to change the pump or lower head [can not start] 1, lack of phase
2, impeller stuck
3, winding, connector or cable break
4, the stator winding burn out
5, electrical control failure 1, check the line, to repair
2, remove debris
3, check with ohmmeter repair
4, to repair, replace the winding
5, check the controller, repair or exchange 【Stator burnout】 1, two-phase operation
2, pumping medium concentration is too large
3, the impeller stuck or loose
4, seal damage to the motor water
5, loose fasteners caused by motor water 1?
2, diluted with water
3, remove dirt, tighten the nut
4, replace the mechanical seal
5, tighten the bolts Bolt [current is too large] 1, the working voltage is low
2, pipes, impeller blocked
3, pumping liquid density or higher viscosity 1, adjust the working voltage
2, clean up the pipeline and impeller blockage
3, change the density or viscosity of pumping liquid

1.5inch Ratchet Strap

1.5 inch 38mm wide different length highly visible straps with reinforced edges,
Various models of hooks - For a non-marring hold, protecting your cargo and vehicle
Durable- Ratcheting component adjusts the straps from 1ft. to 16 ft. in length to easily and safely secure cargo
LOAD LIMIT - Safe working load limit of 1,100 lbs / break strength of 3,300 lbs
ERGONOMIC RATCHET HANDLE - With angular grip and a premium release lever for ease of use

Cargo Buckle Straps,Auto Ratchet Straps,Cargo Lashing Belt,Ratchet Tie Down Straps,Boat Trailer Straps

WINNERLIFTING SAFETY EQUIPMENT CO., LTD. , https://www.winnerslackline.com