How to calculate the installation area of ​​floor heating

The installation area and the heating area of ​​the electric heating usually have certain errors. Therefore, the correct area calculation should be based on the range of the space that needs heating, that is, the indoor heating area calculated by removing the plane within the wall.


Then, the method for calculating the installation area of ​​electric floor heating is: Take the study room as an example—it is the area where the bookcase is included, not only where the heating cable is laid. Below the general bookcase is not recommended to install electric floor heating, or strictly speaking, can not be paved heating cable; there are bay windows need to increase the bay window area, if the bay window area is greater than 1.5 square meters, then the area of ​​the bay window should be in accordance with 2 times the actual area. Take the living room as an example - including the foyer, dining room, living room and aisle area. If the decoration of the kitchen is an open-decoration process and there is no door cut off from the restaurant, then the area of ​​the kitchen is also strictly increased. The kitchen calculates the construction area including the area of ​​the cabinet. Why do you want to do this? Because you want to increase the thermal load in the room, balance the room temperature.

Electric floor heating installation area is how to calculate? Electric floor heating calculation area reasons:

Generally, all the inner area of ​​the jacket needs the supplement of thermal energy. During the heating process, the thermal energy of the electric floor heating not only acts on the area of ​​the heating cable pavement, but also affects all the space and space within the area. Objects; therefore, such as wardrobes, beds, TV cabinets, cabinets, etc., need heat supplements. For example, the installed floor heating power is 150W per square meter, and some of these areas require no floor heating, such as cabinets or coverings. However, places that do not have floor heating also need heat to supplement them. If heat is not added in time, There will be heat loss, weakening the original configuration of 150W per square meter, because the space of unpaved floor heating will grab heat from other places. The actual pavement is often more than 150 W per square meter of 120mm paving distance (Hamburger heating cable power 19.6w/m)



Usually, the consumption of thermal energy will increase as the area of ​​the floating window increases; therefore, the conventional heating design load cannot meet the normal heating demand. By the same token, the workload of construction will not be reduced because there are fixed objects in the area. Instead, the heat cables that should be evenly distributed should be used to artificially release the fixed items. Instead, the workload is increased, that is, heat supplementation and construction. The technical content of personnel. Therefore, under normal circumstances, the installation of electricity floor heating area - the actual heating area!

Shanghai Shure Environmental Technology Co., Ltd. Tel

Aerospace/Military/Aviation Autoclave

Composite Curing Autoclave,Autoclave For Carbon Fiber,Autoclave For Composite Material,Autoclave For Composite Parts

JIANGSU OLYMSPAN THERMAL ENERGY EQUIPMENT CO.,LTD , https://www.compositesautoclave.com